1000
video
1000

1000 kVt yuk banki

1000 kVt yuk banki uyda va chet elda eng katta talabga ega bo'lgan yuk banklaridan biridir. U turli xil generator to'plamlarining chiqish quvvati va yuk ko'tarish qobiliyatini aniq sinab ko'rishi, asosan generator to'plamlarining barcha elektr parametrlarini sinab ko'rishi va yuqori-quvvatli generator uskunalari uchun ilmiy aniqlash vositalarini taqdim etishi mumkin.

1


MAHSULOTGA UMUMI


1000 kVt yuk banki uyda va chet elda eng katta talabga ega bo'lgan yuk banklaridan biridir. U turli xil generator to'plamlarining chiqish quvvati va yuk ko'tarish qobiliyatini aniq sinab ko'rishi, asosan generator to'plamlarining barcha elektr parametrlarini sinab ko'rishi va yuqori-quvvatli generator uskunalari uchun ilmiy aniqlash vositalarini taqdim etishi mumkin. 1000 kVt yuk banki sof rezistiv yuk bo'lib, quvvat iste'moli komponentlari maxsus qotishma rezistorlar, zanglamaydigan po'latdan yasalgan qoplama, kichik harorat drifti va uzoq xizmat muddati bilan o'ralgan. Bitta mashinaning umumiy quvvati 1000 kVtgacha. Tashqi shassi qattiq konteyner tuzilishini qabul qiladi va optimallashtirilgan segmentlangan quvvat kiritish rejimini qabul qiladi. Tegishli quvvat sozlamalari kaliti ishlash parametrlarini aniqlash talablariga muvofiq tortilishi mumkin. U 10kVt-1000kVt oralig'ida birlashtirilishi va o'zboshimchalik bilan o'rnatilishi mumkin. Qadam qiymati 10 kVtni tashkil etadi, bu o'rnatish uchun qulay.


MAHSULOT RASMI




MAHSULOT RASMI




QO'LLANISH SENARIOSI



QISMAN PARAMETRLAR



Eslatma: barcha parametrlar faqat ma'lumot uchun va moslashtirilgan bo'lishi mumkin

Mahsulot nomi

1000 kVt yuk banki

Texnik xususiyatlari

R1000kVt/400V/50Hz

Shakllanish

Bitta yuk banki (shu jumladan quruq qarshilik yuki, elektr boshqaruv komponentlari, o'lchash va nazorat qilish tizimi)

Yuklash bosqichi

Mijozlarning ehtiyojlariga ko'ra

Ulanishni yuklash

Mis bar

Rezistor

Each resistance element: insulation impedance DC1000V/100MΩ above

5 daqiqa davomida 2000v o'zgaruvchan kuchlanishga bardosh bering

Resistance error of each resistance tube:±3 percent

Yukni boshqarish

Mahalliy qo'lda boshqarish, mahalliy avtomatik boshqaruv yoki masofadan avtomatik boshqaruvni tanlash mumkin

Yuklash aniqligi

3 foizdan kam yoki unga teng

Uch fazali muvozanat

Balanssizlik darajasi 3 foizdan kam yoki unga teng

Minimal qadam

1 kVt

Ish rejimi

Doimiy ish

Yukni himoya qilish

Qisqa tutashuv, haddan tashqari oqim, yuqori harorat, fan xatosidan himoya qilish

Tashqi quvvat

TN-C,380V/50Hz

Sovutish rejimi

Majburiy havo sovutish, yon havo chiqishi yoki yuqori havo chiqishi

Izolyatsiya klassi

F

O'lchov aniqligi

Displey aniqligi {0}}.5, namuna olish aniqligi 0,2

Elektr parametrlarini ko'rsatish

Uch fazali kuchlanish, uch{0}}fazali oqim, chastota, quvvat va h.k

Yukni kengaytirish

Bir nechta yuk konteynerlarini parallel ravishda kengaytirish

Standart

Xalqaro standart, kema standarti, harbiy standart va telekommunikatsiya standartiga javob bering

Transport

Yuk ko'taruvchi idish-yuk ko'taruvchi teshikka ega bo'lib, uzoq masofalarga tashish talablariga javob beradi-

Rang

Moslashtirilgan

Atrof-muhit harorati

-20 darajadan 50 darajagacha

Namlik

100 foizgacha

Balandlik

2500 m gacha

Atmosfera bosimi

86 dan 106 kPa gacha


QO'ShIMChA XUSUSIYATLAR



Eslatma: barcha parametrlar faqat ma'lumot uchun va moslashtirilgan bo'lishi mumkin

Quvvat (kVt)

Voltaj (kV)

Chastotasi(Hz)

Hajmi (mm, LWH)

Og'irligi (Kg)

Past kuchlanish

100

0.4

50

11009001000

320

200

0.4

50

135011001100

450

300

0.4

50

150012001200

650

400

0.4

50

170015001500

830

500

0.4

50

170016001600

950

600

0.4

50

180016001600

1150

800

0.4

50

190018001700

1900

1000

0.4

50

230017002100

2100

1200

0.4

50

250018002200

2300

1500

0.4

50

250018602300

2600

1800

0.4

50

300020002300

4000

2000

0.4

50

300020002300

5000

2500

0.4

50

400024382500

6000

3000

0.4

50

600024382500

7000

O'rtacha kuchlanish

1000

6/10.5

50/60

300024382500

3500

1200

6/10.5

50/60

400024382500

3900

1500

6/10.5

50/60

400024382500

4500

1600

6/10.5

50/60

500024382500

5000

1800

6/10.5

50/60

500024382500

6500

2000

6/10.5

50/60

600024382500

7500

2200

6/10.5

50/60

600024382500

8000

2500

6/10.5

50/60

600024382500

10000

3000

6/10.5

50/60

700024382500

12000

4000

6/10.5

50/60

800024382500

14000

5000

6/10.5

50/60

900024382500

15000

6000

6/10.5

50/60

1200024382500

16000

7000

6/10.5

50/60

1200024382500

17000

8000

6/10.5

50/60

1200024382500

18000


DIZAYN CHIZMALARI


image009


TRANSPORT VA OʻRNATISH



image011

Yuk ko'tarish, tashish va mobil o'rnatishni osonlashtirish uchun yuk bankining yuqori to'rtta burchagi ko'taruvchi teshiklar bilan ta'minlangan va pastki to'rtta burchakda rulolar mavjud.


TUZISH BO'YICHA KO'RSATMALAR


(1) Uskunaning quvvat simini ulanishi to'g'ri bo'lishi kerak, ayniqsa, ishlaydigan quvvat manbaining fazalar ketma-ketligi noto'g'ri bo'lishi mumkin, bu fanning teskari aylanishiga olib kelmasligi va uskunaning normal ishlashi mumkin emas.

(2) Before using the equipment, determine that the equipment (secondary circuit) is in a normal state, and the 500V of ground insulation is not less than 1 MΩ.

(3) Jihozni anormal kuchlanishda ishlatish qat'iyan man etiladi.

(4) Uskunani ishlatishdan oldin xavfsiz va ishonchli tarzda erga ulangan bo'lishi kerak.

(5) Uskunaning yomon issiqlik tarqalishiga yo'l qo'ymaslik va uskunaning normal ishlashiga yo'l qo'ymaslik uchun uskunaning kirish va chiqish joyidan 2 metr masofada hech qanday to'siq bo'lmasligi kerak.

(6) Favqulodda to'xtash tugmasi bosilgandan so'ng, favqulodda to'xtatish tugmachasini tiklamaslik va yukni to'satdan tiklamaslik uchun uskunani yuklash tugmasi qayta o'rnatilishi kerak.

(7) Sinov jarayonida elektr toki urishiga yo'l qo'ymaslik uchun elektr energiyasini iste'mol qilish xavfsizligiga e'tibor bering.

(8) Uskunalar yarim yil davomida jihoz ichida chang bilan ishlov berilishi va changyutgich bilan tozalanishi kerak. Foydalanish muhiti nisbatan yomon bo'lsa, uskunaga texnik xizmat ko'rsatish oralig'i mos ravishda qisqartirilishi kerak.

(9) Ventilyator uskunadan foydalanish vaqtida engil tebranishga ega. 2,{2}} soat foydalanishdan keyin fan moslamalari mustahkamlanadi.

(10) Agar uskunada bo'yoq shikastlanishi aniqlansa, uni o'z vaqtida ta'mirlang.


FAXRIY MALAKA


Tashkil etilganidan buyon Rata 16 ta foydali modelga patent sertifikati va 8 ta kompyuter dasturlari uchun mualliflik huquqini roʻyxatdan oʻtkazish sertifikatiga ega boʻldi va milliy yuqori{2}}texnologik korxona sifatida tan olingan.



Issiq teglar: 1000kw yuk banki, Xitoy, etkazib beruvchilar, ishlab chiqaruvchilar, zavod, moslashtirilgan, narx, kotirovka

Keyingi2: 1 MVt yuk banki

(0/10)

clearall