1000 kVt yuk banki
1000 kVt yuk banki uyda va chet elda eng katta talabga ega bo'lgan yuk banklaridan biridir. U turli xil generator to'plamlarining chiqish quvvati va yuk ko'tarish qobiliyatini aniq sinab ko'rishi, asosan generator to'plamlarining barcha elektr parametrlarini sinab ko'rishi va yuqori-quvvatli generator uskunalari uchun ilmiy aniqlash vositalarini taqdim etishi mumkin.
MAHSULOTGA UMUMI
1000 kVt yuk banki uyda va chet elda eng katta talabga ega bo'lgan yuk banklaridan biridir. U turli xil generator to'plamlarining chiqish quvvati va yuk ko'tarish qobiliyatini aniq sinab ko'rishi, asosan generator to'plamlarining barcha elektr parametrlarini sinab ko'rishi va yuqori-quvvatli generator uskunalari uchun ilmiy aniqlash vositalarini taqdim etishi mumkin. 1000 kVt yuk banki sof rezistiv yuk bo'lib, quvvat iste'moli komponentlari maxsus qotishma rezistorlar, zanglamaydigan po'latdan yasalgan qoplama, kichik harorat drifti va uzoq xizmat muddati bilan o'ralgan. Bitta mashinaning umumiy quvvati 1000 kVtgacha. Tashqi shassi qattiq konteyner tuzilishini qabul qiladi va optimallashtirilgan segmentlangan quvvat kiritish rejimini qabul qiladi. Tegishli quvvat sozlamalari kaliti ishlash parametrlarini aniqlash talablariga muvofiq tortilishi mumkin. U 10kVt-1000kVt oralig'ida birlashtirilishi va o'zboshimchalik bilan o'rnatilishi mumkin. Qadam qiymati 10 kVtni tashkil etadi, bu o'rnatish uchun qulay.
MAHSULOT RASMI
MAHSULOT RASMI
QO'LLANISH SENARIOSI
QISMAN PARAMETRLAR
Eslatma: barcha parametrlar faqat ma'lumot uchun va moslashtirilgan bo'lishi mumkin | |
Mahsulot nomi | 1000 kVt yuk banki |
Texnik xususiyatlari | R1000kVt/400V/50Hz |
Shakllanish | Bitta yuk banki (shu jumladan quruq qarshilik yuki, elektr boshqaruv komponentlari, o'lchash va nazorat qilish tizimi) |
Yuklash bosqichi | Mijozlarning ehtiyojlariga ko'ra |
Ulanishni yuklash | Mis bar |
Rezistor | Each resistance element: insulation impedance DC1000V/100MΩ above 5 daqiqa davomida 2000v o'zgaruvchan kuchlanishga bardosh bering Resistance error of each resistance tube:±3 percent |
Yukni boshqarish | Mahalliy qo'lda boshqarish, mahalliy avtomatik boshqaruv yoki masofadan avtomatik boshqaruvni tanlash mumkin |
Yuklash aniqligi | 3 foizdan kam yoki unga teng |
Uch fazali muvozanat | Balanssizlik darajasi 3 foizdan kam yoki unga teng |
Minimal qadam | 1 kVt |
Ish rejimi | Doimiy ish |
Yukni himoya qilish | Qisqa tutashuv, haddan tashqari oqim, yuqori harorat, fan xatosidan himoya qilish |
Tashqi quvvat | TN-C,380V/50Hz |
Sovutish rejimi | Majburiy havo sovutish, yon havo chiqishi yoki yuqori havo chiqishi |
Izolyatsiya klassi | F |
O'lchov aniqligi | Displey aniqligi {0}}.5, namuna olish aniqligi 0,2 |
Elektr parametrlarini ko'rsatish | Uch fazali kuchlanish, uch{0}}fazali oqim, chastota, quvvat va h.k |
Yukni kengaytirish | Bir nechta yuk konteynerlarini parallel ravishda kengaytirish |
Standart | Xalqaro standart, kema standarti, harbiy standart va telekommunikatsiya standartiga javob bering |
Transport | Yuk ko'taruvchi idish-yuk ko'taruvchi teshikka ega bo'lib, uzoq masofalarga tashish talablariga javob beradi- |
Rang | Moslashtirilgan |
Atrof-muhit harorati | -20 darajadan 50 darajagacha |
Namlik | 100 foizgacha |
Balandlik | 2500 m gacha |
Atmosfera bosimi | 86 dan 106 kPa gacha |
QO'ShIMChA XUSUSIYATLAR
Eslatma: barcha parametrlar faqat ma'lumot uchun va moslashtirilgan bo'lishi mumkin | ||||
Quvvat (kVt) | Voltaj (kV) | Chastotasi(Hz) | Hajmi (mm, LWH) | Og'irligi (Kg) |
Past kuchlanish | ||||
100 | 0.4 | 50 | 11009001000 | 320 |
200 | 0.4 | 50 | 135011001100 | 450 |
300 | 0.4 | 50 | 150012001200 | 650 |
400 | 0.4 | 50 | 170015001500 | 830 |
500 | 0.4 | 50 | 170016001600 | 950 |
600 | 0.4 | 50 | 180016001600 | 1150 |
800 | 0.4 | 50 | 190018001700 | 1900 |
1000 | 0.4 | 50 | 230017002100 | 2100 |
1200 | 0.4 | 50 | 250018002200 | 2300 |
1500 | 0.4 | 50 | 250018602300 | 2600 |
1800 | 0.4 | 50 | 300020002300 | 4000 |
2000 | 0.4 | 50 | 300020002300 | 5000 |
2500 | 0.4 | 50 | 400024382500 | 6000 |
3000 | 0.4 | 50 | 600024382500 | 7000 |
O'rtacha kuchlanish | ||||
1000 | 6/10.5 | 50/60 | 300024382500 | 3500 |
1200 | 6/10.5 | 50/60 | 400024382500 | 3900 |
1500 | 6/10.5 | 50/60 | 400024382500 | 4500 |
1600 | 6/10.5 | 50/60 | 500024382500 | 5000 |
1800 | 6/10.5 | 50/60 | 500024382500 | 6500 |
2000 | 6/10.5 | 50/60 | 600024382500 | 7500 |
2200 | 6/10.5 | 50/60 | 600024382500 | 8000 |
2500 | 6/10.5 | 50/60 | 600024382500 | 10000 |
3000 | 6/10.5 | 50/60 | 700024382500 | 12000 |
4000 | 6/10.5 | 50/60 | 800024382500 | 14000 |
5000 | 6/10.5 | 50/60 | 900024382500 | 15000 |
6000 | 6/10.5 | 50/60 | 1200024382500 | 16000 |
7000 | 6/10.5 | 50/60 | 1200024382500 | 17000 |
8000 | 6/10.5 | 50/60 | 1200024382500 | 18000 |
DIZAYN CHIZMALARI
TRANSPORT VA OʻRNATISH
Yuk ko'tarish, tashish va mobil o'rnatishni osonlashtirish uchun yuk bankining yuqori to'rtta burchagi ko'taruvchi teshiklar bilan ta'minlangan va pastki to'rtta burchakda rulolar mavjud.
TUZISH BO'YICHA KO'RSATMALAR
(1) Uskunaning quvvat simini ulanishi to'g'ri bo'lishi kerak, ayniqsa, ishlaydigan quvvat manbaining fazalar ketma-ketligi noto'g'ri bo'lishi mumkin, bu fanning teskari aylanishiga olib kelmasligi va uskunaning normal ishlashi mumkin emas.
(2) Before using the equipment, determine that the equipment (secondary circuit) is in a normal state, and the 500V of ground insulation is not less than 1 MΩ.
(3) Jihozni anormal kuchlanishda ishlatish qat'iyan man etiladi.
(4) Uskunani ishlatishdan oldin xavfsiz va ishonchli tarzda erga ulangan bo'lishi kerak.
(5) Uskunaning yomon issiqlik tarqalishiga yo'l qo'ymaslik va uskunaning normal ishlashiga yo'l qo'ymaslik uchun uskunaning kirish va chiqish joyidan 2 metr masofada hech qanday to'siq bo'lmasligi kerak.
(6) Favqulodda to'xtash tugmasi bosilgandan so'ng, favqulodda to'xtatish tugmachasini tiklamaslik va yukni to'satdan tiklamaslik uchun uskunani yuklash tugmasi qayta o'rnatilishi kerak.
(7) Sinov jarayonida elektr toki urishiga yo'l qo'ymaslik uchun elektr energiyasini iste'mol qilish xavfsizligiga e'tibor bering.
(8) Uskunalar yarim yil davomida jihoz ichida chang bilan ishlov berilishi va changyutgich bilan tozalanishi kerak. Foydalanish muhiti nisbatan yomon bo'lsa, uskunaga texnik xizmat ko'rsatish oralig'i mos ravishda qisqartirilishi kerak.
(9) Ventilyator uskunadan foydalanish vaqtida engil tebranishga ega. 2,{2}} soat foydalanishdan keyin fan moslamalari mustahkamlanadi.
(10) Agar uskunada bo'yoq shikastlanishi aniqlansa, uni o'z vaqtida ta'mirlang.
FAXRIY MALAKA
Tashkil etilganidan buyon Rata 16 ta foydali modelga patent sertifikati va 8 ta kompyuter dasturlari uchun mualliflik huquqini roʻyxatdan oʻtkazish sertifikatiga ega boʻldi va milliy yuqori{2}}texnologik korxona sifatida tan olingan.
Issiq teglar: 1000kw yuk banki, Xitoy, etkazib beruvchilar, ishlab chiqaruvchilar, zavod, moslashtirilgan, narx, kotirovka