AC
video
AC

AC qarshilikli yuk banki

R103kw / 400V / 50Hz yuk banki kompaniyamiz tomonidan ishlab chiqilgan va ishlab chiqarilgan o'zgaruvchan yuk bankidir. Yuklash banki quvvat koeffitsienti 1,0 bo'lgan 25 foizlik muvozanat sinovini o'tkazishi mumkin.

1


MAHSULOTGA UMUMI


R103kw / 400V / 50Hz yuk banki kompaniyamiz tomonidan ishlab chiqilgan va ishlab chiqarilgan o'zgaruvchan yuk bankidir. Yuklash banki quvvat koeffitsienti 1,0 bo'lgan 25 foizlik muvozanat sinovini o'tkazishi mumkin. U uch{6}}fazali to'rt simli tizimni qabul qiladi va generatorlar, transformatorlar, kuchaytirgichlar va boshqa elektr ta'minoti uskunalari uchun qo'lbola yuk sinovini o'tkazishi mumkin.


MAHSULOT RASMI




QO'LLANISH SENARIOSI



QISMAN PARAMETRLAR



Eslatma: barcha parametrlar faqat ma'lumot uchun va moslashtirilgan bo'lishi mumkin

Mahsulot nomi

AC rezistiv yuk banki

Texnik xususiyatlari

R500kVt/400V/690V/50Hz

Shakllanish

Bitta yuk banki (shu jumladan quruq qarshilik yuki, elektr boshqaruv komponentlari, o'lchash va nazorat qilish tizimi)

Yuklash bosqichi

Mijozlarning ehtiyojlariga ko'ra

Ulanishni yuklash

Mis bar

Rezistor

Each resistance element: insulation impedance DC1000V/100MΩ above

5 daqiqa davomida 2000v o'zgaruvchan kuchlanishga bardosh bering

Resistance error of each resistance tube:±3 percent

Yukni boshqarish

Mahalliy qo'lda boshqarish, mahalliy avtomatik boshqaruv yoki masofadan avtomatik boshqaruvni tanlash mumkin

Yuklash aniqligi

3 foizdan kam yoki unga teng

Uch fazali muvozanat

Balanssizlik darajasi 3 foizdan kam yoki unga teng

Minimal qadam

1 kVt

Ish rejimi

Doimiy ish

Yukni himoya qilish

Qisqa tutashuv, haddan tashqari oqim, yuqori harorat, fan xatosidan himoya qilish

Tashqi quvvat

TN-C,380V/50Hz

Sovutish rejimi

Majburiy havo sovutish, yon havo chiqishi yoki yuqori havo chiqishi

Izolyatsiya klassi

F

O'lchov aniqligi

Displey aniqligi {0}}.5, namuna olish aniqligi 0,2

Elektr parametrlarini ko'rsatish

Uch fazali kuchlanish, uch{0}}fazali oqim, chastota, quvvat va h.k

Yukni kengaytirish

Bir nechta yuk konteynerlarini parallel ravishda kengaytirish

Standart

Xalqaro standart, kema standarti, harbiy standart va telekommunikatsiya standartiga javob bering

Rang

Moslashtirilgan

Atrof-muhit harorati

-20 darajadan 50 darajagacha

Namlik

100 foizgacha

Balandlik

2500 m gacha

Atmosfera bosimi

86 dan 106 kPa gacha


QO'ShIMChA XUSUSIYATLAR



Eslatma: barcha parametrlar faqat ma'lumot uchun va moslashtirilgan bo'lishi mumkin

Quvvat (kVt)

Voltaj (kV)

Chastotasi(Hz)

Hajmi (mm, LWH)

Og'irligi (Kg)

Past kuchlanish

100

0.4

50

11009001000

320

200

0.4

50

135011001100

450

300

0.4

50

150012001200

650

400

0.4

50

170015001500

830

500

0.4

50

170016001600

950

600

0.4

50

180016001600

1150

800

0.4

50

190018001700

1900

1000

0.4

50

230017002100

2100

1200

0.4

50

250018002200

2300

1500

0.4

50

250018602300

2600

1800

0.4

50

300020002300

4000

2000

0.4

50

300020002300

5000

2500

0.4

50

400024382500

6000

3000

0.4

50

600024382500

7000

O'rtacha kuchlanish

1000

6/10.5

50/60

300024382500

3500

1200

6/10.5

50/60

400024382500

3900

1500

6/10.5

50/60

400024382500

4500

1600

6/10.5

50/60

500024382500

5000

1800

6/10.5

50/60

500024382500

6500

2000

6/10.5

50/60

600024382500

7500

2200

6/10.5

50/60

600024382500

8000

2500

6/10.5

50/60

600024382500

10000

3000

6/10.5

50/60

700024382500

12000

4000

6/10.5

50/60

800024382500

14000

5000

6/10.5

50/60

900024382500

15000

6000

6/10.5

50/60

1200024382500

16000

7000

6/10.5

50/60

1200024382500

17000

8000

6/10.5

50/60

1200024382500

18000


TRANSPORT VA OʻRNATISH



image008

Yuk ko'tarish, tashish va mobil o'rnatishni osonlashtirish uchun yuk bankining yuqori to'rtta burchagi ko'taruvchi teshiklar bilan ta'minlangan va pastki to'rtta burchakda rulolar mavjud.


YUKOR STANDARTLAR


Tizimni loyihalash, ishlab chiqarish va xizmat ko'rsatish sifat menejmenti tizimining (GB / T19001-2008) talablariga qat'iy muvofiq bo'lishi kerak va quyidagi standartlarga (ulardan ba'zilari amaliy qo'llash uchun mos kelmasligi mumkin va yakuniy ishlab chiqarishga mos kelmasligi mumkin) Tizim sxemasi ikkala tomon tomonidan kelishilgan texnik kelishuvga bo'ysunadi):

Milliy standart

GB/T 2820.5-2009 Pistonli ichki yonuv dvigatelli o'zgaruvchan tok generatorlari 5-qism: generator to'plamlari

GB/T 13032-2010 Dengiz dizel generatorlari to'plami

GB / T 1029-2005 Uch fazali sinxron motorlar uchun sinov usullari

GB 14711-2006 Kichik va o'rta aylanadigan elektr mashinalari uchun xavfsizlik talablari

Harbiy standart

GJB 5785-2006 Harbiy ichki yonish generatorlari to'plamining umumiy tavsifi

GJB 235-1997 Harbiy AC mobil elektr stantsiyasining umumiy spetsifikatsiyasi

GJB 1488-92 Harbiy ichki yonish dvigatelini quvvat bilan ta'minlash uchun umumiy sinov usuli


FAXRIY MALAKA


Tashkil etilganidan buyon Rata 16 ta foydali modelga patent sertifikati va 8 ta kompyuter dasturlari uchun mualliflik huquqini roʻyxatdan oʻtkazish sertifikatiga ega boʻldi va milliy yuqori{2}}texnologik korxona sifatida tan olingan.



Issiq teglar: AC rezistiv yuk banki, Xitoy, etkazib beruvchilar, ishlab chiqaruvchilar, zavod, moslashtirilgan, narx, kotirovka

(0/10)